Flow Solutions
EN   AR   glevents

Explore

Our Products

Our wide range of high-quality products includes power generators and cooling solutions to meet your specific requirements.

 

As the leading temporary power solution provider in Dubai, we understand the importance of reliable power supply for your construction projects, events, and emergency situations. Our generator rental services in Dubai offer a seamless and efficient backup power solution, ensuring uninterrupted operations and peace of mind.

 

With a focus on stability and dependability, our power generator rental services in Dubai are designed to meet your electricity needs, no matter the scale of your project. Count on us to provide you with a consistent power source, allowing you to concentrate on your core activities.

 

When it comes to temporary power solutions in Dubai, our generator hire services are unmatched. Tailored to your project timeline and budget, our offerings provide you with the flexibility and convenience you require for short-term power requirements.

 

For heavy-duty power needs, our diesel generator rental in Dubai delivers robust performance, making them ideal for industrial applications, construction projects, and remote locations. You can rely on these generators to ensure optimal performance and efficiency for your critical operations.

 

In addition to our exceptional power generators, we also offer cutting-edge cooling and HVAC solutions to tackle the extreme temperatures in the UAE and Middle East. Our cooling systems create comfortable environments for your event, workforce and equipment, contributing to the smooth functioning of your projects.

 

With a wealth of experience in the industry, we understand the diverse needs of our clients. Our expert team is ready to assist you in choosing the right equipment and offering on-site technical support when required.

 

At FLOW, we prioritize quality, reliability, and customer satisfaction. Our well-maintained and tested products ensure seamless performance throughout their rental period, so you can focus on your project’s success.

GEH2V3 100kVA Hydrogen Generator
Overview
ManufacturerEODev
Model No.GEH2V3
Frequency50
Ambient Temperature40 °C
Fuel CapacityExternal Required
Prime Power100 kVA / 80 kW
Continuous Power75kVA / 60 kW
Hydrogen Tank Pressure200 Bar
Inlet Pressure9-16 Bar
Current Output144 A

Pagoda

Available Sizes

3m x 3m, 5m x 5m, 6m x 6m, 8m x 8m, 12m x 12m

Cladding:

Cladding: ABS, Glass, PVC

Perfect for:

Shades, F&B Stalls, Small Offices, Sponsor Activations, BOH Areas, Site Compounds, Security & Checkpoints

Pagoda

Available Sizes

3m x 3m, 5m x 5m, 6m x 6m, 8m x 8m, 12m x 12m

Cladding:

Cladding: ABS, Glass, PVC

Perfect for:

Shades, F&B Stalls, Small Offices, Sponsor Activations, BOH Areas, Site Compounds, Security & Checkpoints

GEH2V3 100kVA Hydrogen Generator
Overview
ManufacturerEODev
Model No.GEH2V3
Frequency50
Ambient Temperature40 °C
Fuel CapacityExternal Required
Prime Power100 kVA / 80 kW
Continuous Power75kVA / 60 kW
Hydrogen Tank Pressure200 Bar
Inlet Pressure9-16 Bar
Current Output144 A
GEH2V3 100kVA Hydrogen Generator
Overview
ManufacturerEODev
Model No.GEH2V3
Frequency50
Ambient Temperature40 °C
Fuel CapacityExternal Required
Prime Power100 kVA / 80 kW
Continuous Power75kVA / 60 kW
Hydrogen Tank Pressure200 Bar
Inlet Pressure9-16 Bar
Current Output144 A
GEH2V3 100kVA Hydrogen Generator
Overview
ManufacturerEODev
Model No.GEH2V3
Frequency50
Ambient Temperature40 °C
Fuel CapacityExternal Required
Prime Power100 kVA / 80 kW
Continuous Power75kVA / 60 kW
Hydrogen Tank Pressure200 Bar
Inlet Pressure9-16 Bar
Current Output144 A

Generators

GEH2V3 100kVA Hydrogen Generator
Overview
ManufacturerEODev
Model No.GEH2V3
Frequency50
Ambient Temperature40 °C
Fuel CapacityExternal Required
Prime Power100 kVA / 80 kW
Continuous Power75kVA / 60 kW
Hydrogen Tank Pressure200 Bar
Inlet Pressure9-16 Bar
Current Output144 A

EVENT POWER DISTRIBUTION BOARDS

FDB 600
IncomerOutgoingDimensionsWeight
FDB 1132A/3ph6 x 16A/1phH: 270 mm
W: 230 mm
D: 230 mm
6 kg
FDB 1232A/3ph1 x 32A/3ph
9 x 16A/1ph
H: 340 mm
W: 400 mm
D: 350 mm
12 kg
FDB 12A32A/3ph1 x 32A/3ph
9 x 16A/1ph
H: 340 mm
W: 400 mm
D: 350 mm
12 kg
FDB 1432A/3ph1 x 32A/3ph
3 x 32A/1ph
3 x 16A/1ph
H: 340 mm
W: 400 mm
D: 350 mm
6 kg
FDB 1632A/3ph1 x 32A/3ph
6 x 32A/1ph
6 x 16A/1ph
H: 450 mm
W: 550 mm
D: 495 mm
28 kg
FDB 1732A/3ph1 x 32A/3ph
6 x 16A/1ph
H: 270 mm
W: 290 mm
D: 270 mm
12 kg
FDB 4232A/1ph4 x 16A/1ph
H: 90mm
W: 415mm
D: 120mm
3 kg
FDB 4332A/1ph8 x 16A/1phH: 450 mm
W: 190 mm
D: 160 mm
8 kg
FDB 2163A/3ph1 x 63A/3ph
2 x 32A/3ph
6 x 32A/1ph
6 x 16A/1ph
H: 450 mm
W: 550 mm
D: 490 mm
31 kg
FDB 21A63A/3ph1 x 63A/3ph
2 x 32A/3ph
6 x 32A/1ph
6 x 16A/1ph
H: 450 mm
W: 550 mm
D: 490 mm
31 kg
FDB 2663A/3ph3 x 32A/3ph
3 x 32A/1ph
6 x 16A/1ph
H: 340 mm
W: 560 mm
D: 350 mm
20 kg
FDB 2763A/3ph3 x 32A/3ph
3 x 32A/1ph
H: 300 mm
W: 300 mm
D: 350 mm
12 kg
FDB 30125A/3ph2 x 63A/3ph
2 x 32A/3ph
3 x 32A/1ph
6 x 16A/1ph
H: 600 mm
W: 550 mm
D: 495 mm
38 kg
FDB 30A125A/3ph2 x 63A/3ph
2 x 32A/3ph
3 x 32A/1ph
6 x 16A/1ph
H: 600 mm
W: 550 mm
D: 495 mm
38 kg
FDB 31125A/3ph1 x 63A/3ph
3 x 32A/3ph
3 x 32A/1ph
6 x 16A/1ph
H: 600 mm
W: 550 mm
D: 495 mm
35 kg
FDB 32125A/3ph1 x 63A/3ph
2 x 32A/3ph
12 x 32A/1ph
6 x 16A/1ph
H: 600 mm
W: 550 mm
D: 495 mm
46 kg
FDB 35125A/3ph6 x 32A/3phH: 600 mm
W: 550 mm
D: 495 mm
45 kg
FDB 36125A/3ph5 x 32A/3ph
2 x 32A/3ph
4 x 16A/1ph
H: 450 mm
W: 550 mm
D: 500 mm
45 kg
FDB 37125A/3ph2 x 63A/3ph
3 x 32A/3ph
H: 450 mm
W: 550 mm
D: 500 mm
45 kg
FDB 400400A/3ph1 x 400A/3ph
4 x 125A/3ph
H: 1092 mm
W: 612 mm
D: 495 mm
95 kg
FDB 401250A/3ph10 x 32A/3phH: 800 mm
W: 620 mm
D: 500 mm
115 kg
FDB 402400A/3ph1 x 400A/3ph
3 x 125A/3ph
3 x 63A/3ph
3 x 63A/1ph
3 x 32A/3ph
2 x 16A/1ph
H: 1390 mm
W: 610 mm
D: 495 mm
110 kg
FDB 403400A/3ph1 x 400A/3ph
3 x 125A/3ph
3 x 63A/3ph
4 x 32A/3ph
3 x 32A/1ph
6 x 16A/1ph
H: 1390 mm
W: 610 mm
D: 495 mm
80 kg
FDB 403A400A/3ph3 x 125A/3ph
3 x 63A/3ph
4 x 32A/3ph
3 x 32A/1ph
6 x 16A/1ph
H: 1390 mm
W: 610 mm
D: 495 mm
80 kg
FDB 405400A/3ph1 x 400A/3ph
3 x 125A/3ph
3 x 63A/3ph
3 x 32A/3ph
3 x 32A/1ph
12 x 16A/1ph
H: 1200 mm
W: 610 mm
D: 495 mm
110 kg
FDB 406400A/3ph2 x 125/3ph
4 x 63/3ph
H: 1092 mm
W: 612 mm
D: 495 mm
95 kg
FDB 600600A/3ph2 x 400A/3phH: 800 mm
W: 620 mm
D: 500 mm
100 kg

HVAC's

Handling UNIT & CHILLER

200RT Air Handling Unit
Air Flow11,300 L/s
Cooling Coil Capacity739 kWm
Ext. Pressure1100 Pa
Total Pressure1918 Pa
Fuel CapacityExternal Required
Power Supply400 V / 3 Phase
Frequency50 Hz
Supply Duct Size6 x 500 mm
Return Duct Size6 x 500 mm
Weight2750 kg
DimensionsL: 6000 mm
W: 2350 mm
H: 3000mm
200RT Chiller
Cooling Capacity200RT
Power Supply380 - 415 V / 3 Phase
Frequency50 Hz
Minimum Circuit Ampacity475 A
Maximum Over Current Protection664 A
RefrigerantR134A
Compressor / Total Power Input261.6 kW / 286.6 kW
Water Flow Rate484.7 GPM
Entering / Leaving Water Temperature12.2 °C / 5 °C
Compressor TypeSemi Hermetic Screw
DimensionsL: 6000 mm
W: 2350 mm
H: 3000mm

Extractors

1500 CFM EXTRACTOR
Design Volume1500 CFM
Power Supply220 - 240 V / 3 Phase
Frequency50 Hz
Starting Current12 A
Running Current8 A
Duct Size300 mm
Weight30 kg
DimensionsL: 800 mm
W: 1150 mm
H: 640 mm
3000 CFM EXTRACTOR
Design Volume3000 CFM
Power Supply400 V / 3 Phase
Frequency50 Hz
Starting Current18 A
Running Current15 A
Duct Size300 mm
Weight65 kg
DimensionsL: 1160 mm
W: 880 mm
H: 920 mm
4500 CFM EXTRACTOR
Design Volume4500 CFM
Power Supply400 V / 3 Phase
Frequency50 Hz
Starting Current20 A
Running Current16 A
Duct Size300 mm
Weight80 kg
DimensionsL: 1250 mm
W: 950 mm
H: 1150 mm
6000 CFM EXTRACTOR
Design Volume6000 CFM
Power Supply400 V / 3 Phase
Frequency50 Hz
Starting Current23 A
Running Current12 A
Duct Size500 mm
Weight125 kg
DimensionsL: 1580 mm
W: 1220 mm
H: 1150 mm

Packaged AC Units

5RT Package Unit
Cooling Capacity5RT / 18 kWm
Power Supply380 - 400 V / 3 Phase
Frequency50 Hz
Starting Current15 A
Running Current14 A
RefrigerantR410 / R22
Weight175 kg
DimensionsL: 1380 mm
W: 1030 mm
H: 1050 mm
10RT Package Unit
Cooling Capacity10RT / 35 kWm
Power Supply380 - 400 V / 3 Phase
Frequency50 Hz
Starting Current38 A
Running Current21 A
RefrigerantR410 / R22
Weight525 kg
DimensionsL: 2670 mm
W: 1910 mm
H: 1490 mm
15RT Package Unit
Cooling Capacity15RT / 55 kWm
Power Supply380 - 400 V / 3 Phase
Frequency50 Hz
Starting Current58 A
Running Current34 A
RefrigerantR410 / R22
Weight840 kg
DimensionsL: 1130 mm
W: 1965 mm
H: 1230 mm
25RT Package Unit (MIDEA)
Cooling Capacity25RT / 90 kWm
Power Supply380 - 400 V / 3 Phase
Frequency50 Hz
Starting Current105 A
Running Current61 A
RefrigerantR410 / R22
Weight2100 kg
DimensionsL: 2220 mm
W: 2320 mm
H: 1250 mm
25RT Package Unit (SKM)
Cooling Capacity24.09RT / 85 kWm
Power Supply380 - 415 V / 3 Phase
Frequency50 Hz
Starting Current140 A
Running Current57.4 A
RefrigerantR410
Weight2100 kg
DimensionsL: 2662 mm
W: 2235 mm
H: 1845 mm

Split AC Units

2RT SPLIT AC
Cooling Capacity2RT / 7 kWm
Power Supply220 - 240 V / 1 Phase
Frequency50 Hz
Starting Current13 A
Running Current10 A
RefrigerantR410 / R22
Weight (Indoor)18 kg
Weight (Outdoor)52 kg
Dimensions (Indoor)L: 1080 mm
W: 226 mm
H: 336 mm
Dimensions (Outdoor)L: 845 mm
W: 363 mm
H: 702 mm
4RT SPLIT AC
Cooling Capacity4RT / 7 kWm
Power Supply220 - 240 V / 1 Phase
Frequency60 Hz
Starting Current31 A
Running Current26 A
RefrigerantR22
Weight (Indoor)54kg
Weight (Outdoor)111 kg
Dimensions (Indoor)L: 610 mm
W: 360 mm
H: 1900 mm
Dimensions (Outdoor)L: 1060 mm
W: 550 mm
H: 1580 mm
5RT SPLIT AC
Cooling Capacity5RT / 18 kWm
Power Supply400 V / 3 Phase
Frequency50 Hz
Starting Current18 A
Running Current11 A
RefrigerantR22
Weight (Indoor)65kg
Weight (Outdoor)114 kg
Dimensions (Indoor)L: 610 mm
W: 360 mm
H: 1900 mm
Dimensions (Outdoor)L: 990 mm
W: 440 mm
H: 1360 mm
6RT SPLIT AC
Cooling Capacity6RT / 18 kWm
Power Supply400 V / 3 Phase
Frequency50 Hz
Starting Current19 A
Running Current14 A
RefrigerantR22
Weight (Indoor)125kg
Weight (Outdoor)160 kg
Dimensions (Indoor)L: 1050 mm
W: 550 mm
H: 1950 mm
Dimensions (Outdoor)L: 840 mm
W: 800 mm
H: 1710 mm
8RT SPLIT AC
Cooling Capacity8RT / 30 kWm
Power Supply400 V / 3 Phase
Frequency50 Hz
Starting Current26 A
Running Current17 A
RefrigerantR410 / R22
Weight (Indoor)175 kg
Weight (Outdoor)195 kg
Dimensions (Indoor)L: 1200 mm
W: 450 mm
H: 1950 mm
Dimensions (Outdoor)L: 1520 mm
W: 920 mm
H: 1110 mm
10RT SPLIT AC
Cooling Capacity10RT / 35 kWm
Power Supply400 V / 3 Phase
Frequency50 Hz
Starting Current32 A
Running Current24 A
RefrigerantR410
Weight (Indoor)175 kg
Weight (Outdoor)195 kg
Dimensions (Indoor)L: 1200 mm
W: 450 mm
H: 1950 mm
Dimensions (Outdoor)L: 1520 mm
W: 920 mm
H: 1110 mm

Flow Air & Power Solution LLC

Jebel Ali, Industrial Area 2
P.O. Box 191731, Dubai,
United Arab Emirates (UAE)

2022 © Flow Solutions